Hourly Analysis Heat Load Calculation , Equipment's configuration , Selection of Equipments & Energy Analysis

Hourly Analysis Program (HAP Software)

Hourly Analysis Heat Load Calculation , Equipment’s configuration , Selection of Equipments & Energy Analysis
Notes de 3,8 sur 5
14 Avis
198  Sessions

Ce que vous allez apprendre dans ce cours

Détails

Description

System components are sized using System-Based Design, which tailors sizing procedures to the specific system type. Energy modeling uses full 8760 hours-per-year analysis to evaluate the operation of a wide variety of HVAC system types.

HAP is designed for consulting engineers, design/build contractors, HVAC contractors, facility engineers and other professionals involved in the design and analysis of commercial building HVAC systems. The program is a powerful tool for designing systems and sizing system components as well as modeling annual energy performance and energy costs.

Carrier’s Hourly Analysis Program is two powerful tools in one package – versatile features for designing HVAC systems for commercial buildings AND powerful energy analysis capabilities for comparing energy consumption and energy costs of design alternatives.

By combining both tools in one package, significant time savings are achieved. Input data and results from system design calculations can be used directly in energy modeling studies.

HAP is designed for consulting engineers, design/build contractors, HVAC contractors, facility engineers and other professionals involved in the design and analysis of commercial building HVAC systems.

The program is a powerful tool for designing systems and sizing system components. HAP can easily handle projects involving:

Small to large commercial buildings;

Systems including rooftops, variable refrigerant flow (VRF) central air handlers, WSHPs, GSHPs, fan coils, chilled water and hot water plants and more;

Many types of constant volume and VAV system controls;

Small office buildings, retail stores, strip shopping centers, schools, churches, restaurants, large office buildings, hotels, malls, hospitals, factories, and multi-use buildings; and

New design, retrofit or energy conservation work.

À qui ce cours s’adresse-t-il ?
It gives detailed explanation of Heat Load calculation , System configuration , equipment selection & Energy Analysis of entire system
Afficher plus

Hourly Analysis Heat Load Calculation , Equipment's configuration , Selection of Equipments & Energy Analysis

19,99 €
Redirection avec pop-up et nouvel onglet
Redirection double
Redirection double avec deux onglets

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Cours similaires

Propulsez vos connaissances !

Tous les sujets que vous souhaitez apprendre sont sur Coursselly ! N’attendez plus pour découvrir les formations !

Rejoindre la #commu

Profitez d’avantages exclusifs et de nouvelles fraîches chaque semaine.

19,99 €
Redirection avec pop-up et nouvel onglet